Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros

Asunto principal
Tipo del documento
Intervalo de año
1.
Kathmandu Univ Med J (KUMJ) ; 20(79): 337-341, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-2293196

RESUMEN

Background The Coronavirus disease 2019 (COVID-19) pandemic caused by the severe acute respiratory syndrome coronavirus (SARS-CoV-2) has spread worldwide since its first recorded case in the city of Wuhan, China, in December 2019. SARS-CoV-2 infection causes asymptomatic to sever pneumonia. Severe cases may develop acute respiratory disease symdrome (ARDS), with an average mortality rate of 6.9%. Real Time Reverse Transcriptase Polymerase Chain Reaction (rRT-PCR) assay is the current reference standard laboratory method for the diagnosis of SARS-CoV-2 infection. However, it takes around 6-8 hours to get the result and is time consuming. Therefore, rapid and accurate tests for SARS-CoV-2 screening are essential to expedite disease prevention and control. Lateral flow immunoassay using monoclonal anti SARS-CoV-2 antibodies which target for SARS-CoV-2 antigen can be complimentary screening test if their accuracy were comparable to that of the real time reverse transcriptionpolymerase chain reaction (RT-PCR) assay. Objective To find the sensitivity and specificity of a rapid antigentest kit in comparison to reverse transcription-polymerase chain reaction (RT-PCR). Method A cross-sectional hospital based study was carried out at Shree Birendra Army Hospital, Kathmandu for a period of four months. Result Our finding shows sensitivity and specificity of rapid diagnostic tests (RDT) Ag kit as 60.6% and 96.4% respectively. Positive and negative predictive value was 83.7% and 89.0%. Likewise, positive and negative likelihood ratio was 17.0 and 0.4. The overall accuracy of the antigen kit was 88.1% in comparison to reverse transcriptionpolymerase chain reaction (RT-PCR) as the gold standard. Conclusion Our study concluded the use of rapid antigen kit is mainly useful for screening purposes.


Asunto(s)
COVID-19 , Humanos , SARS-CoV-2 , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Centros de Atención Terciaria , Estudios Transversales , Prueba de COVID-19
2.
Kathmandu University Medical Journal ; 20(79):207-211, 2022.
Artículo en Inglés | EMBASE | ID: covidwho-2156617

RESUMEN

Background The Coronavirus disease 2019 (COVID-19) pandemic caused by the severe acute respiratory syndrome coronavirus (SARS-CoV-2) has spread worldwide since its first recorded case in the city of Wuhan, China, in December 2019. SARS-CoV-2 infection causes asymptomatic to sever pneumonia. Severe cases may develop acute respiratory disease symdrome (ARDS), with an average mortality rate of 6.9%. Real Time Reverse Transcriptase Polymerase Chain Reaction (rRT-PCR) assay is the current reference standard laboratory method for the diagnosis of SARS-CoV-2 infection. However, it takes around 6-8 hours to get the result and is time consuming. Therefore, rapid and accurate tests for SARS-CoV-2 screening are essential to expedite disease prevention and control. Lateral flow immunoassay using monoclonal anti SARS-CoV-2 antibodies which target for SARS-CoV-2 antigen can be complimentary screening test if their accuracy were comparable to that of the real time reverse transcription-polymerase chain reaction (RT-PCR) assay. Objective To find the sensitivity and specificity of a rapid antigentest kit in comparison to reverse transcription-polymerase chain reaction (RT-PCR). Method A cross-sectional hospital based study was carried out at Shree Birendra Army Hospital, Kathmandu for a period of four months. Result Our finding shows sensitivity and specificity of rapid diagnostic tests (RDT) Ag kit as 60.6% and 96.4% respectively. Positive and negative predictive value was 83.7% and 89.0%. Likewise, positive and negative likelihood ratio was 17.0 and 0.4. The overall accuracy of the antigen kit was 88.1% in comparison to reverse transcription-polymerase chain reaction (RT-PCR) as the gold standard. Conclusion Our study concluded the use of rapid antigen kit is mainly useful for screening purposes. Copyright © 2022, Kathmandu University. All rights reserved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA